The OTC DAIHEN EP400 / EP500 Series represents high-end fully digital welding machines designed for high-quality, high-demand welding environments. Not only does this series perfectly handle conventional carbon steel and stainless steel, but its derived models are also widely recognized in the industry as the “Aluminum Welding Benchmark.” To precisely match different material characteristics and heat dissipation requirements, the original manufacturer has classified up to 5 standard factory configurations for the EP series. This article will provide a detailed breakdown of these five configuration lists, along with authoritative wire feeding system selection guidance, to help you avoid procurement pitfalls.
1. Welding Expert Guide: Revealing Core Hardware Differences in EP Series Configurations
Purchasing the wrong wire feeder or cooling system will directly lead to wire jamming, arc extinguishing, or even burning the torch. Before reviewing the lists, please look for the following technical identifiers:
- Look for the Aluminum Welding Exclusive Code (A): A main unit model with an “A” (e.g., EP-500A) indicates that the power source is deeply optimized for aluminum alloy waveforms. A wire feeder with an “A” (e.g., CMA-6401 / CMAW-6401) indicates it uses internal U-groove drive rolls and Teflon liners, specifically targeting extremely soft aluminum welding wire to prevent crushing and deformation.
- Conventional Steel Welding Exclusive Code (E): Wire feeders with an “E” (e.g., CME-6401 / CMWE-6401) are dedicated to hard welding wires like carbon steel/stainless steel, utilizing internal V-groove drive rolls to provide powerful feeding thrust.
- Air-Cooled vs. Water-Cooled: “W” stands for Water-cooled. When conducting continuous operations at high currents over 400A, the heat at the torch head spikes. A water-cooled torch with a “W” (e.g., WTAW5000-BD) and a matching wire feeder must be used, connected to an external circulating water tank; otherwise, consumables will burn out rapidly.
2. EP400 Standard Factory Configuration List (400A Class)
2.1 EP400 Air-Cooled Standard Steel Configuration
Application Scenarios: High-efficiency, low-spatter welding of conventional carbon steel/stainless steel plates. The system is lightweight and eliminates water-circuit maintenance.
| NO. | Core Component Name | Original Model/Spec | Qty |
|---|---|---|---|
| 1 | Welding Power Source | EP-400 | 1 Unit |
| 2 | Standard Steel Wire Feeder | CME-6401 | 1 Unit |
| 3 | Air-Cooled GMAW Torch | WT3510-BD | 1 PC |
| 4 | Gas Flow Meter | W-50FL-Ar | 1 Set |
| 5 | Gas Inlet Hose | K5857 | 1 PC |
| 6 | Wire Feeder Control Cable | QK0072B00 | 1 PC |
| 7 | Secondary Ground Cable | BKPT-5002 | 1 PC |
3. EP500 Air-Cooled Standard Factory Configuration Lists (500A Class)
3.1 EP500A Air-Cooled Standard Aluminum Configuration (Dedicated for Aluminum)
Application Scenarios: Tack welding of medium-to-thick aluminum plates, and welding of heavy aluminum components without extreme long seams.
| NO. | Core Component Name | Original Model/Spec | Qty |
|---|---|---|---|
| 1 | Advanced Dedicated Al Welding Power Source | EP-500A | 1 Unit |
| 2 | Dedicated Aluminum Wire Feeder | CMA-6401 | 1 Unit |
| 3 | Air-Cooled Aluminum GMAW Torch | WTA300-D | 1 PC |
| 4 | Gas Flow Meter | W-50FL-Ar | 1 Set |
| 5 | Gas Inlet Hose | K5857 | 1 PC |
| 6 | Wire Feeder Control Cable | QK0072B00 | 1 PC |
| 7 | Secondary Ground Cable | BKPT-7002 | 1 PC |
3.2 EP500 Air-Cooled Standard Steel Configuration (Heavy Industry Conventional)
| NO. | Core Component Name | Original Model/Spec | Qty |
|---|---|---|---|
| 1 | Heavy-Duty Welding Power Source | EP-500 | 1 Unit |
| 2 | Standard Steel Wire Feeder | CME-6401 | 1 Unit |
| 3 | Air-Cooled Heavy-Duty GMAW Torch | WT5000-BD | 1 PC |
| 4 | Gas Flow Meter | W-50FL-Ar | 1 Set |
| 5 | Gas Inlet Hose | K5857 | 1 PC |
| 6 | Wire Feeder Control Cable | QK0072B00 | 1 PC |
| 7 | Secondary Ground Cable | BKPT-7002 | 1 PC |
4. EP500 Heavy-Duty Water-Cooled Configuration Lists (Extreme Mass Production Type)
⚠️ Expert Reminder: When selecting the following water-cooled configuration kits, the customer site must provide or additionally purchase an industrial-grade external circulating cooling water tank. Dry burning the welding torch without water is strictly prohibited.
4.1 EP500A Water-Cooled Standard Aluminum Configuration (Highly Recommended)
Application Scenarios: High-current continuous automatic or semi-automatic welding for marine aluminum alloy prefabricated parts and high-speed rail aluminum car bodies.
| NO. | Core Component Name | Original Model/Spec | Qty |
|---|---|---|---|
| 1 | Advanced Dedicated Al Welding Power Source | EP-500A | 1 Unit |
| 2 | Water-Cooled Dedicated Al Wire Feeder | CMAW-6401 | 1 Unit |
| 3 | Water-Cooled Heavy-Duty Al GMAW Torch | WTAW5000-BD | 1 PC |
| 4 | Gas Flow Meter | W-50FL-Ar | 1 Set |
| 5 | Gas Inlet Hose | K5857 | 1 PC |
| 6 | Wire Feeder Control Cable | QK0072B00 | 1 PC |
| 7 | Secondary Ground Cable | BKPT-7002 | 1 PC |
4.2 EP500 Water-Cooled Standard Steel Configuration (Torch Space Reserved)
This configuration includes dedicated water-cooling components but does not include a standard welding torch, allowing the factory to freely select a customized automated water-cooled torch based on the specific flange interface of the dedicated machine or robot.
| NO. | Core Component Name | Original Model/Spec | Qty |
|---|---|---|---|
| 1 | Heavy-Duty Welding Power Source | EP-500 | 1 Unit |
| 2 | Water-Cooled Standard Steel Wire Feeder | CMWE-6401 | 1 Unit |
| 3 | Gas Flow Meter | W-50FL-Ar | 1 Set |
| 4 | Gas Inlet Hose | K5857 | 1 PC |
| 5 | Wire Feeder Control Cable | QK0072B00 | 1 PC |
| 6 | Secondary Ground Cable | BKPT-7002 | 1 PC |
| 7 | Water-Cooling Core Component | P30221X00 | 1 Set |