EP400 Error Codes List: E000 to E911 Troubleshooting Guide

During the operation of the OTC DAIHEN EP400 welding machine, if a fault occurs, the display panel will pop up the corresponding abnormal alarm code. To assist maintenance technicians in quickly locating the problem, we have compiled a comprehensive troubleshooting guide covering common error codes from E000 to E911, along with official solutions.

OTC EP400 Abnormal Alarm Code Quick Reference Table

Alarm Code Abnormality Description Solution / Countermeasure
E000 Terminals [STOP] Disconnected Confirm if the external terminal block TM5 [STOP] (34) is open-circuited. To clear the abnormality, set function [F4].
E010 Torch Switch OFF Wait Confirm if the torch trigger/switch is stuck in the ON position upon startup.
E020 Inching Feed OFF Wait Confirm if the wire inching switch is stuck in the ON position.
E030-E037 USB Communication Error Check the USB drive connection, re-insert it, and restart the power.
E040-E042 Startup Communication Error This will disappear upon restarting the power supply.
E050-E059 Control Board Communication Error This will disappear upon restarting the power supply.
E100 Control Power Supply Error Check the +24V and ±15V power supplies. Restart the power.
E150 Input Overvoltage Confirm if the input voltage is within the 342-418V range. Restart the power.
E160 Input Undervoltage Confirm the input voltage is 342-418V. Check function [F20] settings.
E200 Primary Current Detector Error Check the contact status of the P30099P_CN25 connector.
E210 Arc Voltage Detection Error Check the welding cable and detection wire for open circuits or short circuits.
E220 Primary Main Circuit Error Confirm if the internal IGBT module is damaged.
E230 Primary Drive Error Check P30099P_CN21-CN24 connectors and test the waveforms.
E240 Secondary Current Detector Error Check the P30099P_CN29 connector on the circuit board.
E260 Voltage Detection Loop Error Check the P30099P_CN27 connector on the circuit board.
E301 Primary IGBT Side Temp Error Confirm P30099P_CN11 connector. Check the duty cycle and ambient temperature.
E302 Secondary DR Side Temp Error Confirm P30099P_CN12 connector. Check the duty cycle and ambient temperature.
E615 Memory Backup Warning Press any key to clear. Check if saved welding conditions have been initialized.
E700 Output Overcurrent Error Check if the contact tip is touching the base metal, or if the welding cable is short-circuited.
E710 W-Phase Loss Error Check the primary input cables and distribution wiring.
E800-E801 Wire Feeder Encoder Error Check the wire feeder control connections and motor status.
E810 Wire Feed Motor Drive Temp Error Check the torch and wire feeder for jammed welding wire.
E850 Wire Feeder Control Power Error Check P30087Q_CH2-CH1 24V power supply.
E860 Wire Feed Motor Power Error Check P30087Q_CH10-CH9 48V power supply.
E900-E907 Software Error If restarting fails to clear the error, please contact an authorized agent.
E910-E911 OS Error If restarting fails to clear the error, please contact an authorized agent.